The BW Solo single gas detector is a reusable monitor, designed to reduce costs whilst still ensuring workers are protected and compliant.

Please note: there are currently long lead times on the BW Solo HCN models. Check with our Sales Team for expected delays and up to date information.

This single gas detector is available in numerous configurations including O2, CO, H2S, NH3, CO2, SO2, HCN, CL2, NO, NO2, PH3, ETO, CLO2, O3 and H2. It has a typical battery life of 6-12 months, depending on the type of sensor chosen. The Solo is the first single gas detector to use 1-series sensors for CO, H2S and O2. This makes it highly accurate, fast-responding but at a low cost.

It’s easy to maintain and the sensors, batteries and sensor filters can be replaced without having to take the unit apart. There's an option to activate the Intelliflash or non-compliance flash to show at a glance that the unit is ready to be used in operation. It comes with a triple alarm system showing a visual alarm, vibrating alarm and audible alarm when gas is present.

Key Features

  • Can be used with the IntelliDox for automatic bump and calibration
  • Simple user interface which is easy to read
  • Remote visibility on alarms
  • Ability to assign detectors to different workers and locations
  • Data logging with rolling 24-hour peak reading
  • IP66/68 rated
  • Carries out self-test and checks sensor integrity, battery, circuitry and alarms

Specifications

Size

2.7 x 2.6 x 1.4 in. / 7.0 x 6.7x 3.6 cm (1-Series sensor models) `

2.7 x 2.6 x 1.6 in. / 7.0 x 6.7x 4.1 cm (4-Series sensor models)

Weight

3.6 to 4.1 oz. / 103 to 116 g, depending on installed sensor

Humidity

0% - 95% RH (non-condensing)

Typical Battery Life

12 months (6 months for 1-Series O2 and 4 months for 1S CO2)

User Options

Reset TWA, STEL and Peak readings
Change High, Low, TWA and STEL alarm setpoints
Latching alarms
Enable IntelliFlash and non-compliance indicators
Set calibration and/or bump test reminders
Assign worker and location assignments
Language select: English, French, Spanish, German, Italian, Russian, Japanese, Chinese, Korean, Portuguese, Dutch (Honeywell BW™ Solo Lite*: English, Russian, Japanese, Chinese and Korean only)

Approvals

n: Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, AEx/Ex ia IIC T4 Ga -40°C≤ Tamb ≤ 60°C
ATEX*: Sira 18ATEX2243 X 2460 g II 1G Ex ia IIC T4 Ga g I M1 Ex ia I Ma -40°C≤ Tamb ≤ 60°C
IECEx: IECEx SIR 18.0058 Ex ia IIC T4 Ga / Ex ia I Ma -40°C≤ Tamb ≤ 60°C
FCC ID: SU3BWS1
IC: 20969-BWS1
RED: RE-D Directive 2014/53/EU

*CO2 version currently non-ATEX. Approval pending for ATEX.

Warranty

3 years for 1-Series detectors and sensors (H2S, CO, O2)
2 years for 4-Series detectors and sensors
(1 year for NH3, Cl2, O3, ETO, ClO2 sensors)

H2S (Hydrogen Sulphide) – 1 series
(SKU: BWS-HL-Y)

Range – 0-200ppm
Resolution – 0.1ppm
Operating Temp - -40 to +140°F / -40 to +60°C

CO (Carbon Monoxide) – 1 series
(SKU: BWS-ML-Y)

Range – 0-2000ppm
Resolution – 1ppm
Operating Temp - -40 to +140°F / -40 to +60°C

O2 (Oxygen) – 1 series
(BWS-XL-Y)

Range – 0-30% v/v
Resolution – 0.1ppm
Operating Temp - -40 to +140°F / -40 to +60°C

CO2 (Carbon Dioxide) – 1 series**
(BWS-BL-Y)

Range – 0 - 50,000ppm
Resolution – 100ppm
Operating Temp - -4 to +140°F / -20 to +60°C
**Certifications Pending

Cl2 (Chlorine) – 4S
(SKU: BWS-C-Y)

Range – 0-50ppm
Resolution – 0.1ppm
Operating Temp - -4 to +104°F / -20 to +30°C

ClO2 (Chlorine Dioxide) – 4S
(SKU: BWS-V-Y)

Range – 0-1ppm
Resolution – 0.01ppm
Operating Temp - -4 to +104°F / -20 to +30°C

CO-H – 4S
(SKU: BWS-M2-Y)

Range – 0-2000ppm
Resolution – 0.5ppm
Operating Temp - -22 to +122°F / -30 to +50°C

ETO – 4S
(SKU: BWS-E-Y)

Range – 0-100ppm
Resolution – 0.1ppm
Operating Temp - -4 to +104°F / -20 to +40°C

H2 (Hydrogen) – 4S
(SKU: BWS-R-Y)

Range – 0-1000ppm
Resolution – 2ppm
Operating Temp - -4 to +122°F / -20 to +50°C

H2S (Hydrogen Sulphide EXT) – 4S
(SKU: BWS-H2-Y)

Range – 0-500ppm
Resolution – 0.1ppm
Operating Temp - -40 to +122°F / -40 to +50°C

HCN (Hydrogen Cyanide) 4S
(SKU: BWS-Z-Y)

Range – 0-100ppm
Resolution – 0.1ppm
Operating Temp - -22 to +122°F / -30 to +50°C

NH3 (Ammonia) 4S -
(SKU: BWS-A-Y)

Range – 0-100ppm
Resolution – 1ppm
Operating Temp - -4 to +104°F / -20 to +50°C

NH3-Ext (Ammonia) 4S
(SKU: BWS-A2-Y)

Range – 0-1000ppm
Resolution – 1ppm
Operating Temp - -4 to +104°F / -20 to +50°C

NO (Nitric Oxide) 4S
(SKU: BWS-N-Y)

Range – 0-250ppm
Resolution – 0.2ppm
Operating Temp - -22 to +122°F / -30 to +50°C

NO2 (Nitrogen Dioxide) 4S
(SKU: BWS-D-Y)

Range – 0-100ppm
Resolution – 0.1ppm
Operating Temp - -4 to +122°F / -20 to +50°C

O3 (Ozone) 4S
(SKU: BWS-G-Y)

Range – 0-1ppm
Resolution – 0.01ppm
Operating Temp - -22 to +122°F / -30 to +50°C

PH3 (Phosphine) 4S
(SKU: BWS-P-Y)

Range – 0-5ppm
Resolution – 0.1ppm
Operating Temp - -4 to +122°F / -20 to +50°C

SO2 (Sulphur Dioxide) 4S
(SKU: BWS-S-Y)

Range – 0-100ppm
Resolution – 0.1ppm
Operating Temp - -22 to +122°F / -30 to +50°C

Take advantage of our web-exclusive free UK mainland* delivery offer on orders over £100 ex VAT. See all costs for delivery below and visit our main delivery page for more information on timescales as some restrictions may apply.

UK & Ireland Delivery Options

UK Mainland Standard Delivery on orders under £100 ex VAT - £7.95 ex VAT*
UK Mainland Express Delivery - £21.50 ex VAT (timescales vary – please see delivery page)
Highlands Delivery - £25.00 ex VAT
Channel Island Delivery - £40 ex VAT
Northern Ireland & Republic of Ireland - £25 ex VAT
Saturday Delivery Options – Please contact us on 0141 771 7749 for more info

Standard delivery timescales are normally 3-5 working days, depending on stock availability. Express delivery is normally 1-3 working days, depending on stock availability. Although we carry an extensive stock, there may be some items that are unavailable due to quantities or otherwise. In this case we will inform you of the status of your order and whether or not it can be fulfilled within our standard delivery timeframe.*Mainland UK delivery excludes Northern Ireland, other charges apply.

Please visit our main delivery page for more terms and conditions or contact our Sales Team on 0141 771 7749 or [emailprotected] for more information. Currently, some manufacturers are facing production and delivery issues due to Brexit and custom clearance and this is affecting lead times of even some of our standard stocked items. We're trying our best to prevent these issues from affecting orders but please be aware that there may be some delays. We are aiming to communicate this as best and as early as possible.

International Delivery Options

Delivery costs vary between countries. Please visit our main delivery page for more information.

You also have the option to 'Arrange Your Own Courier', whereby you organise the shipment of your own goods once they have reached our warehouse.

ORDER CANCELLATION AND GOODS RETURN

Should you wish to cancel an order or return unwanted goods please follow the procedures detailed below to help us ensure cancellations/returns are processed as quickly and efficiently as possible.

Simply log on to your customer account, note the order reference number and email the full cancellation details to [emailprotected] or contact us on 0141 771 7749. Assuming the order has not been despatched we will cancel.

You have the right to cancel the purchase of goods without having to give a reason at any time within the “cooling off period” of fourteen working days, beginning the day after you take delivery of your order.

You must notify us of your cancellation in writing via email to [emailprotected] or to our contact address. (Details Here)

If you are in possession of the goods you are under the duty to retain them and take reasonable care of them.

You must send the goods back to us in their original condition to our contact address at your own cost (unless we delivered the item to you in error or the item is damaged or defective) as soon as possible once you have cancelled the contract.

Alternatively we will collect the goods from you which will incur a charge no greater than the actual cost of arranging the collection and shipping. In this case you must make the goods available for collection. We will contact you to make further arrangements.

We reserve the right to make a charge not exceeding our direct costs of recovering the goods if you do not return the goods or return them at our expense.

Upon receipt of returned items in satisfactory condition we will arrange a full credit by the same method used to pay for the goods originally. Any credit due will be processed within a maximum of thirty days.

Note: If you wish to return goods for refund or exchange after 14 days, a re-stocking fee of 20% of the full order total will apply.

If upon receipt of goods you find them to be faulty, damaged or if you have been incorrectly supplied an item, you should notify us within 24 hours by contacting 0141 771 7749 or [emailprotected] and quoting your order number and contact details.

Frontline Safety will arrange uplift of any damaged or wrongly received goods and if on inspection of goods we also find them to be damaged, faulty or incorrectly supplied, we will offer replacement goods or provide a full refund.

We recommend you inspect all goods prior to signing for and accepting delivery. If there is any visible damage to the outer packaging, ensure goods are sign for as damaged. In instances where it isn’t possible to sign for goods as damaged, these should be signed for as unexamined.


Note: If your goods happen to develop a fault out with the standard returns period but within supplied warranty period or if you require any additional assistance, please contact us on 0141 771 7749 or email [emailprotected]

IMPORTANT INFORMATION

All postage, handling, customs and duty charges for all returned goods are the responsibility of the customer. We recommend using a fully traceable, insured service as goods are your responsibility while in transit.

Honeywell BW Solo Serviceable Single Gas Detector (2024)

FAQs

How do I reset my Honeywell gas detector? ›

In order to reset a GasAlert Extreme, you just have to take off the battery and leave like that for 24 hours and then put the battery back again, that will reset the unit.

What gas does the Honeywell Solo monitor use? ›

The first single-gas detector with the 1 Series sensor for CO, H2S, O2, and CO.

How do you calibrate a Honeywell gas detector? ›

The display will indicate the first configuration mode menu 'SEt CAL'. Put the magnet over the 'ü' switch again and move to enter the Calibration menu. The display will show the current gas reading, and the gas canister icon flashes. When the zero gas reading is stable use 'ü' to confirm zero calibration.

How do single gas detectors work? ›

How do Disposable Single Gas Detectors Work? The disposable single gas monitors use one single sensor to detect levels of one single gas type where the users can set the alarm set points to their gas detection needs.

Where is the Honeywell reset button? ›

Make sure your thermostat is on. Press and hold the “Set” button on the left side of the user interface. While holding down the “Set” button, use a paper clip or another slender object to press the recessed reset button located on the side of the unit to the right of the user interface.

How do you troubleshoot a gas detector? ›

Check the operating temperature range to see if the weather is causing the problem. For fixed gas detectors, check the power cable for damage. Test the amount of voltage going into the device. If there's no voltage, inspect the fuse connectors going in and out of the marshaling cabinet.

What is the difference between a gas monitor and a gas detector? ›

One of the most important differences is that a monitor can be portable, allowing workers to clip them onto their uniforms when heading to work in an area that might have gas leaks. Many of the monitors are personal-use ones, and the addition of them to your commercial building can be a great benefit to your employees.

What is the disadvantage of gas monitor? ›

Only one gas can be measured with each instrument. When heavy dust, steam or fog blocks the laser beam, the system will not be able to take measurements. This is also the case when a person or vehicle blocks the path.

Are single gas monitors designed to detect a single specific gas? ›

Single gas detectors are designed to detect one specific type of gas or vapor. They are often used for monitoring environments where the presence of a particular gas is expected or where there is a specific concern about a particular gas.

How often do gas detectors need to be calibrated? ›

Calibration is recommended annually or if bump testing indicates an out of spec sensor. Due to the technology of electrochemical sensors, they will deplete over time and more rapidly if exposed to the target gas. They can also be poisoned if exposed to certain gases.

Can I calibrate my own gas detector? ›

This can be done manually with a regulator, calibration gas, calibration cap and tubing. Or it can be done automatically with the use of a calibration docking station, such as the Galaxy GX2.

What are the two main reasons for gas detector failure? ›

Gas interference: Cross interference from other gases can compromise the performance of a gas sensor, altering the calibration curve will result in false or inaccurate readings. Component failure: Like everything else your gas detectors are prone to wear and tear.

How do I know if my gas detector is working? ›

Bump testing is the only way to ensure the sensors and alarm on your portable gas detector are functioning properly. A bump test involves exposing the detector's sensors to a concentration of gas that is greater than the alarm set points. If the sensors are working properly the alarm will go off.

What is the main problem in using gas filled detectors? ›

The main problem is the small size of the voltage pulse that is produced by the interaction of a single quantum of radiation. The deposition of 1 MeV of energy in an ion chamber with a typical capacitance of 100 picofarads (pF) results in a voltage pulse with amplitude of only about 50 microvolts (μV).

Honeywell BW™ Solo Single-Gas Detector ...Procon Systemshttps://www.proconsystems.com ›

Honeywell BW™ Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-are...
Honeywell BWTM SoloServiceable Single-Gas DetectorThe Honeywell BWTM Solo is easy to operate and service and includes an extensive selection of sensor options. ...
Honeywell BW Solo is an easy to service single-gas detector with bluetooth enabled connectivity that provides real-time visibility into the status and safety of...

How do I reset my Honeywell sensor? ›

Reset the sensor by pressing and holding the Connect button on the sensor until the orange light appears (after about 15 seconds). Then try adding the sensor to the thermostat again.

How to reset gas detector alarm? ›

Here's how to reset your carbon monoxide detector:
  1. Find the Reset button. It's on the front panel, though the exact location and size of the button vary by brand and model.
  2. Press and hold the Reset button for 5 to 10 seconds.
  3. Release the Reset button, and listen for a beep. Some models may also flash a light.

Top Articles
Kitchen Nightmares Anna Vincenzo S Cece Weight Loss - Option Pit
Branding über Instagram: "Für The Shade Room ist Instagram der effektivste Kanal." - FUTUREBIZ
Bannerlord Campaign Or Sandbox
Alvin Isd Ixl
Zachary Zulock Linkedin
It May Surround A Charged Particle Crossword
LensCrafters Review for September 2024 | Best Contact Lens Stores
Busted Newspaper Longview Texas
Ketchum Who's Gotta Catch Em All Crossword Clue
Dr. Nicole Arcy Dvm Married To Husband
Mayo Webscheduler
Best Charter Schools Tampa
When His Eyes Opened Chapter 3096
Uca Cheerleading Nationals 2023
Soul Attraction Rs3
Adams County 911 Live Incident
Sheetz Unlimited Drinks Ending
30+ useful Dutch apps for new expats in the Netherlands
18002226885
12 Best Junk Removal in Jackson, MS
Walmart Careers Stocker
Greensboro, NC Breaking News Headlines Today | Ground News
Uhaul L
1773X To
Sdn Upstate 2023
Pwc Transparency Report
How 'Tuesday' Brings Death to Life With Heart, Humor, and a Giant Bird
Biopark Prices
Dicks Sporting Good Lincoln Ne
Durrell: The Alexandria Quartet - The Modern Novel
Official Klj
What Is The Solution To The Equation Below Mc010-1.Jpg
Windows 10 Defender Dateien und Ordner per Rechtsklick prüfen
Savannah Schultz Leaked
Stony Brook Citrix Login
Agility Armour Conan Exiles
Greg Teaches An Art Class
Lenscrafters Westchester Mall
Mychart University Of Iowa Hospital
Jacksonville Jaguars should be happy they won't see the old Deshaun Watson | Gene Frenette
Loss Payee And Lienholder Addresses And Contact Information Updated Daily Free List Gm Financial Lea
Viaggio Apostolico a Singapore: Santa Messa nello Stadio Nazionale presso il “Singapore Sports Hub” (12 settembre 2024)
[PDF] (Indices und Systematiken) - Free Download PDF
Pinellas Fire Active Calls
The Penitent One Unmasked
Obtaining __________ Is A Major And Critical Closure Activity.
How Did Kratos Remove The Chains
Tacoma Craigslist Free
Acadis Portal Missouri
Erfolgsfaktor Partnernetzwerk: 5 Gründe, die überzeugen | SoftwareOne Blog
Craigslist Farm And Garden Lexington
Sammyflood
Latest Posts
Article information

Author: Dong Thiel

Last Updated:

Views: 5673

Rating: 4.9 / 5 (79 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Dong Thiel

Birthday: 2001-07-14

Address: 2865 Kasha Unions, West Corrinne, AK 05708-1071

Phone: +3512198379449

Job: Design Planner

Hobby: Graffiti, Foreign language learning, Gambling, Metalworking, Rowing, Sculling, Sewing

Introduction: My name is Dong Thiel, I am a brainy, happy, tasty, lively, splendid, talented, cooperative person who loves writing and wants to share my knowledge and understanding with you.